                                                                                                      Digestion & Evaporation Systems

DigiPROBE is a PFA coated, temperature sensor which provides                                 DigiPREP Accessories
direct control and monitoring of the actual sample temperature                                           DigiPROBE
during a digestion.
                                                                                                     Features
During digestion or evaporation, sample temperature and block              Probe and wiring is Teflon® coated for acid compatibility
temperature are offset. Since standard temperature control is              Connects to the all blocks (except DigiPREP MINI)
through the block temperature sensor, graphite block users must            Can be calibrated on Keypad and Touch Screen Controllers
calibrate the offset to obtain a suitable control temperature to arrive
at a specific sample temperature. DigiPROBE provides direct
sample temperature feedback to the controller which will then adjust
the temperature of DigiPREP block on a continuous basis to
arrive at the requisite sample temperature.

               Ordering Information

Description                                               Qty Catalog No.

DigiPROBE for 15 ml DigiTUBE                              1 010-515-115    DigiPROBEs are supplied with acid resistant
                                                          1 010-505-115    DigiPROBE holders to support and position the
DigiPROBE for 50 ml DigiTUBE                              1 010-501-115    DigiPROBE in the tube. DigiPROBEs are
                                                                           serialized for traceability.
DigiPROBE for 100 ml DigiTUBE                             1 010-500-032

DigiPROBE Tube, is a Pyrex sheath placed
over the tip of the DigiPROBE. Used
during sample digestion as protection against
cross contamination from multiple sample
rack batches. Acts as a barrier between
high concentrated acidified samples and
the DigiPROBE; extends the life of the
DigiPROBE.

The graph demonstrates the         Temperature (°C)  100                              DigiPROBE
effectiveness of DigiPROBE                            96                              Hot Plate
maintaining a constant sample                         92                              Graphite Block  20                               10
temperature in a diminishing                          88
volume of liquid. This compares                       84  50 40 30
to the loss of sample temperature                     80
with volume on a hot plate                                                             Volume (ml)
or graphite block without
DigiPROBE.

Sample Temperature vs Sample
Volume During Evaporation

(DigiPREP system’s “Target

Temperature” is set to 95 °C)