Page 51 - Catalog Instruments and Supplies
P. 51

SCP SCIENCE 51
                                                                    Microwave Digestion Systems

                                                                        NovaWAVE FA
                                                                    Digestion System

NovaWAVE SA can be upgraded to the fully automated                  A Fully Automated NovaWAVE FA Microwave Tunnel Digestion System
NovaWAVE FA mode through the acquisition of the Transporter         with all the software and operational parameters employed in the Model
and additional racks. With the use of volume calibrated Quartz      NovaWAVE SA; plus the Transporter, Auto-Cooling and Auto-Venting
vessels for most applications and/or TeflonĀ® vessels with HF acid,  Stations to complete the automation.
hundreds of samples can be processed easily in a day.
                                                                    Vessels are placed in racks which are moved under software control into
                                     Graph of                       the microwave tunnel. Twelve microwave mini cavities are dynamically
                                     digestion                      formed and energy is delivered to each mini microwave cavity according
                                     protocol                       to the digestion method selected. On exiting the tunnel, the rack proceeds
                                                                    to the Cooling Station as the second rack enters the tunnel to begin its
                                                                    digestion sequence. Once the digestion of the second rack is completed, it
                                                                    moves to the Cooling Station with the first rack moving to the Auto-Venting
                                                                    Station. Here, vessels are vented automatically when they reach the pre-
                                                                    set temperature assigned in the method.

Automate the SA model with the Transporter System                   Features
allowing automatic processing of up to 14 racks
of 12 samples for a total of 168 samples                                  A mixture of 50 ml or 75 ml racks may be run
                                                                          on the NovaWAVE FA
Auto-Cooling and Auto-Venting Stations complete
the automation process. Samples are ready                                 TeflonĀ® and Quartz vessels may be run in the same rack
for analysis on an ongoing basis                                          at the same time
   46   47   48   49   50   51   52   53   54   55   56