Page 131 - Catalog Instruments and Supplies
P. 131

SCP SCIENCE 131
                                                                                                        Solid Phase Extraction

                                                                                                  DigiSEP
                                                        Molecular Recognition Technology Gel

                                                                              Anions and Halogens

                                                                            specifications

  Product Type                Target Analyte              Matrix     Range  Optimal Flow Rate        Remarks
                                                                      (pH)   (ml / g / minute)
DigiSEP AN-01            SO42-, SeO42-, SeO32-, Cr(VI)   µM (acid)                                 Base elutable
DigiSEP AN-02            SO42-, SeO42-, SeO32-, Cr(VI)     Water     < 3.0              ---        Base elutable
DigiSEP Ha-01                                                        < 9.5              ---     Removal of 100 ppb
DigiSEP F-01                      Cl-, Br-, I-          HNO3, H2SO4  < 2.0             0.5         Base elutable
DigiSEP F-02                          F-                   Water      <4                ---        Base elutable
                                      F-                   Water     <1-8              0.5

                         Ordering Information                               aScuildfuarincdaucsidin(gH2tSheO4a)pispraopproiawteerDfuligoixPidRiziEngP
                                                                            Digestion System (See pg. 41), sulfuric
           Product Type  Cartridge (5 / pk)             Powder (10 g)       acid can digest almost any organic matrix.
                            Catalog No.                  Catalog No.        However, it is extremely viscous, even at low
DigiSEP AN-01                                                               concentrations, and requires long washout
DigiSEP AN-02              010-720-001                  010-790-001         times through the ICP spray chamber. The
DigiSEP Ha-01              010-720-003                  010-790-003         AN-01 cartridge will avoid this problem.
DigiSEP F-01               010-720-005                  010-790-005
DigiSEP F-02               010-720-007                  010-790-007         At present, the only way to digest SiO2
                           010-720-009                  010-790-009         is to use an excess of HF (hydrofluoric
                                                                            acid) which creates problems with ICP
                                                                            spectroscopy. The resulting F- excess can
                                                                            precipitate elements of interest such as
                                                                            Mg and Al. In the past, Boric Acid has been
                                                                            added to the remaining F- ion complex.
                                                                            However, this solution results in a more
                                                                            complex matrix increasing the analytical
                                                                            difficulty. Now with the DigiSEP F-01 and
                                                                            F-02 cartridges, the excess F- ions can be
                                                                            removed.
   126   127   128   129   130   131   132   133   134   135   136