Page 132 - Catalog Instruments and Supplies
P. 132
132 SCP SCIENCE
Solid Phase Extraction
DigiSEP
Molecular Recognition Technology Gel
Transition Metals
Transition metals can represent a challenge in ICP analysis. These important metals can be retained on TE cartridges separating them from other
interfering elements. The eluted transition metals can then be analyzed without the original matrix interferences.
specifications
Product Type Target Analyte Matrix Range Optimal Flow Rate Remarks
(pH) (ml / g / minute)
DigiSEP TE-01
DigiSEP TE-02 Ag+,Au3+, Cd2+, Co2+, Cu2+, Fe2+, Hg2+, Ni2+, Pb2+, Pd2+, Zn2+ Water 4 - 9.5 0.5 Acid elutable, > 1 ppm
Water 4 - 9.5 0.5 6 M HCl elutable, > 0.1 ppm
DigiSEP TE-03 Ag+, Au3+, Cd2+, Co2+, Cu2+, Fe2+, Hg2+, Ni2+, Pb2+, Pd2+, Water 1 - 9.5 0.5 EDTA, 6 M elutable; < 100 ppb
Zn2+, Fe3+, Mn2+ Water 1 - 9.5 0.5 EDTA, 6 M elutable; < 100 ppb
DigiSEP TE-04 Water 1 - 9.5 0.5 Acid elutable
Au3+, Co2+, Cu2+, Hg2+, Fe3+, Pd2+, Zn2+ (all pH range).
DigiSEP TE-05 Ag1+, Cd2+, Pb2+, (pH>3), Cu2+ (pH<3)
DigiSEP TE-06
DigiSEP TE-07 Au3+, Co2+, Cu2+, Hg2+, Ni2+, Pd2+, Zn2+ (all pH range).
DigiSEP TE-09 Ag1+, Cd2+, Pb2+, (pH>3), Cu2+ (pH<3)
DigiSEP TE-10
DigiSEP TE-11 Fe3+, Co3+, Cu2+, Hg2+, Ni2+, In3+, Ga3+, Bi3+, Al3+ (all pH
DigiSEP TE-12 range), Mn2+, Cd2+, Zn2+ and Pb2+ (pH>3)
DigiSEP TE-13
Cu2+ Water 2.0 - 9.5 0.5 Acid elutable
Most 2+, 3+ and 4+ metal ions as a group Water > 2.0 --- 6 M HCl elutable
Ni2+, Zn2+, Cd2+, Co2+, Cu2+, Fr2+, Au3+, Pb2+, Hg2+, Pd2+, Ag2+ Water 4.0 - 9.5 --- ---
Au3+, Hg2+, Pl2+, Cu2+, Ni2+, Co2+, Zn2+ Water 0 - 9.5 --- 6 M HCl elutable
Ni2+, Co2+, Cu2+, Zn2+ Water 0.5 - 2.0 --- 6 M HCl elutable
Ni2+, Co2+, Cu2+, Zn2+ Water 0.5 - 2.0 --- 6 M HCl elutable
Ge2+, Sn4+, MoO42-, borate as a group Multiple 1 - 12 --- HCl elutable
Water 50 ml DigiSEP TE 500 ml / 3 ml Product Type Cartridge (5 / pk) Powder (10 g)
Catalog No. Catalog No.
Add 2 mol / 2 mol / L HNO3 5 ml x 2 DigiSEP TE-01
L Ammonium DI Water 5 ml x 2 DigiSEP TE-02 010-720-071 010-790-071
Acetate to adjust DigiSEP TE-03 010-720-073 010-790-073
pH properly DigiSEP TE-04 010-720-075 010-790-075
DigiSEP TE-05 010-720-077 010-790-077
confirm pH 5 ~ 10 ml / min. DigiSEP TE-06 010-720-079 010-790-079
Sample Loading DigiSEP TE-07 010-720-081 010-790-081
DigiSEP TE-09 010-720-083 010-790-083
1~5 Rinse 1: DI water 5 ml x 2 DigiSEP TE-10 010-720-085 010-790-085
ml / min, DigiSEP TE-11 010-720-087 010-790-087
DigiSEP TE-12 010-720-089 010-790-089
necessary Elute DigiSEP TE-13
optimization 010-720-091 010-790-091
010-720-093 010-790-093
based on Solid a) 1 - 5 mol / L HNO3
Phase b) 0.5 - 1.0 mol / L EDTA-HN4
c) 0.5 - 1.0 mol / L Thiourea
Analysis by Dilution 0.5~10 ml / min.
ICP-OES
DigiSEP TE series Cartridge Application
www.scpscience.com | e-mail: [email protected] | phone: +1 (514) 457-0701