66 SCP SCIENCE                                                            All-in-one COD and Phosphate unattended sample preparation and
          EasyPREP - Laboratory Automation                                    analysis with capping and uncapping capability.

Automated Chemistry Analysis                                                  Automate sample pipetting, mixing, heating, cooling and analysis of
AutoCHEM                                                                      COD and Phosphate samples. Applicable to a variety of other pre-
                                                                              programmed chemistries.
            AutoCHEM
            is designed for                                                   System calibration of dispensing accuracy according to
      Environmental                                                           ISO 8655-5 and compliant with ISO 17025.

                  and                                                         AutoCHEM is designed to run the following testing
     State & Municipal                                                        methods:

             testing labs                                                     •	 COD Potassium Dichromate Method

                                                                              •	 Total Phosphate Method

                                                                              •	 Possibility to analyze other chemistries

Features                                                                    Features

Sample capacity of 67 tubes                                                 Measurement without cuvette slot cover. The advanced optical
Fully automated system from sample pick up to output of results             design is insensitive to external light
Complies with ISO 15705 and EPA 410.4 for COD analysis                      Documentation of results according to GLP
Nephelometric turbidity measurements according to EN ISO 7027               Digestion block with a heating temperature range
Load and track individual samples identified through barcoding              from ambient to 180 ºC.
LIMS compatible output file. Sample ID’s are saved for a full traceability  User friendly software with graphical display of the
                                                                            samples being processed

specifications

Spectrophotometer Technical Data

Wavelength range        340-1100 nm                                         Photometric accuracy: 0.005 E at 0.0 - 0.5 E; 1% at 0.5 - 2.0 E
Wavelength accuracy     ± 1 nm
Wavelength resolution:  0.3 nm                                              Photometric linearity: < 0.5% at 2 E; = 1% at > 2 E
Photometric range:      ± 3.0 E in wavelength range 400-900 nm
                                                                            Stray light:  < 0.5%

                                                                                          E - Illuminance (Watts of illumination/m2)