Page 18 - Catalog Instruments and Supplies
P. 18

18 SCP SCIENCE                                     WHAT DO YOU WANT TO DIGEST?
          Digestion & Evaporation Systems
                                                        HOW ARE YOU PREPARING YOUR
Method Development Guide                                              SAMPLE NOW?
SLIGHTLY REACTIVE samPLES
                                                            HOW REACTIVE ARE YOUR
                                             METHOD                     SAMPLES?
                                        DEVELOPMENT
                                                      HOW MANY SAMPLES DO YOU HAVE?
                                               GUIDE
                                                      Slightly                          Non
                           Highly                     Reactive                       Reactive
                         Reactive                     Samples                        Samples
                         Samples

SLIGHTLY REACTIVE EXAMPLES                            Choose Acid Combination
- Partial Digestion (E.P.A. 3050B)
i.e. Plant (low organic content),

      sludges, soil sample

PlasmaPURE HCl Acid                  PlasmaPURE HNO3 Acid                      PlasmaPURE HNO3/HCl Acids
- Strong non-oxidizing mineral acid  - Strong oxidizing mineral acid           - Very strong oxidizing media
                                     - Sample digested between 80°C and 120°C  - Reacts upon mixing - forms brown fumes upon mixing
- Sample should be below 80°C        - DigiTUBEs, Watch Glasses                - Samples should be digested between 95°C and 110°C
- DigiTUBE, Glass, or Quartz sample                                            - DigiTUBE, Glass, or Quartz sample tubes, Watch Glasses

   tubes, Watch Glasses

                       Below 2 grams                                           Add H202: - Strong oxidizing solution
                  Add up to 10 ml acid                                                         - Cool to room temperature before
                                                                                                  adding peroxide
System Used: DigiPREP MS, Jr., LS, h, MINI &
                           DigiVAC*                                                                    Reheat Sample

      - Below 95°C - Ramp to temperature

                Digest Sample                                                  Filter Sample
* May only be used with DigiPREP MS

                                                      Digestion
                                                      Complete

www.scpscience.com | e-mail: [email protected] | phone: +1 (514) 457-0701